Data-driven decisions for your electrical network.

Power System Studies

Every relay setting, every breaker rating, and every protection coordination curve should be backed by rigorous analysis, not inherited assumptions or guesswork. PACS employs highly experienced power system studies engineers who deliver the analytical foundation your network needs to operate reliably, safely, and in full regulatory compliance.

Our studies have directly resolved live operational problems, including chronic nuisance tripping at the St. Regis Hotel Katara and Qatar Foundation industrial substations, and have informed the protection design for some of Qatar's most complex commercial, district cooling, and high-security facilities. When we deliver a study, we deliver a complete analytical narrative: the network model, the calculations, the settings proposals, and the documentation required for Kahramaa approval, all in one coherent package.

Power System Studies
Service Scope

What We Deliver

A comprehensive scope of services, executed by Protection-licensed engineers with decades of grid-level experience.

01

Load flow analysis and system performance verification

02

Short circuit analysis and fault level calculation

03

Protection coordination studies and relay settings proposals

04

Voltage drop calculations across distribution networks

05

Harmonic simulation and power quality studies

06

Neutral grounding system analysis and design

07

Arc flash studies for LV switchgear panels

08

Motor starting studies for large drive applications

09

Root-cause analysis for panel tripping and nuisance fault events

10

Nuisance tripping investigation, diagnosis, and resolution

11

Protection coordination characteristic curve generation

12

EMTP (Electromagnetic Transients Program)

13

Insulation coordination

14

Grid integration studies for solar and wind

15

EMTP switching studies

16

Complete electrical network study with full calculation report and Kahramaa documentation

17

Kahramaa, Qatar Energy, Client approvals

Recent Work

Projects at a Glimpse

St. Regis Hotel, Katara

Nuisance tripping investigation -> protection coordination study -> revised settings -> Kahramaa approval -> tripping eliminated

Qatar Foundation

11kV chiller feeder tripping -> power system study -> settings revision -> tripping resolved

Oasis Mall

Short circuit and protection coordination for 11kV substation with YY bus configuration

Qatar University

Short circuit and protection coordination for 11kV substation with YY bus configuration

Falcon 5 Project

Load flow, short circuit, and coordination across 25 LV panels (1,000 / 1,600 kVA)

Lusail District Cool Marafeq

Load flow, short circuit, and coordination for 11 MV panels with chiller feeders

Lusail Marina DCP

Full study: network analysis, short circuit, coordination, harmonics, and neutral grounding

ISF (Lekhwiya)

33kV panel: load flow, short circuit, voltage drop, and protection coordination

SW1 Pumping Station, Lusail

11kV relay coordination, motor starting, and root-cause tripping analysis

Lusail North DCP

Full study: coordination, relay settings, motor starting, short circuit, and harmonic analysis

QTEC

Arc flash studies for LV switchgear panels

Ooredoo

Load flow and short circuit studies for LV distribution panels

Qatar Energy

Load Flow Study; Short Circuit Study for 33kV network; Protection ETAP Studies of LV Panel - including load flow calculations with MCCBs ratings, voltage drop calculations, and protection coordination characteristic curves

Al Dayen Coast Guard

11kV protection coordination study for chiller feeder networks

HMC Car Parking

Load flow, short circuit, and coordination for 11kV substation

Al Wakra/Wukair-STP

Protection Coordination Study; Operational Sequence designing

System Analysis

Power System Studies

Load Flow Analysis

One line diagramRas Laffan Project
Load Flow Analysis

Short Circuit Analysis

One line diagramRas Laffan Project
Short Circuit Analysis
Insights & Results

Study Outcomes

Study: TCC Curve Optimization

A comparison of 'Incorrect' vs 'Proper' coordination, demonstrating how our engineers eliminate nuisance tripping and improve grid reliability.

undefined visualization 1

undefined visualization 1
undefined visualization 2
At a Glance

Specifications

Technical parameters and scope parameters that define our service delivery.

Voltage LevelsEHV to LV
DeliverablesStudy reports, relay settings proposals, and full Kahramaa approval documentation
Outcome FocusResolving tripping faults, optimizing protection settings, and supporting network expansion decisions
LicensingETAP with Unlimited Bus Capacity