Every relay setting, every breaker rating, and every protection coordination curve should be backed by rigorous analysis, not inherited assumptions or guesswork. PACS employs highly experienced power system studies engineers who deliver the analytical foundation your network needs to operate reliably, safely, and in full regulatory compliance.
Our studies have directly resolved live operational problems, including chronic nuisance tripping at the St. Regis Hotel Katara and Qatar Foundation industrial substations, and have informed the protection design for some of Qatar's most complex commercial, district cooling, and high-security facilities. When we deliver a study, we deliver a complete analytical narrative: the network model, the calculations, the settings proposals, and the documentation required for Kahramaa approval, all in one coherent package.

A comprehensive scope of services, executed by Protection-licensed engineers with decades of grid-level experience.
Load flow analysis and system performance verification
Short circuit analysis and fault level calculation
Protection coordination studies and relay settings proposals
Voltage drop calculations across distribution networks
Harmonic simulation and power quality studies
Neutral grounding system analysis and design
Arc flash studies for LV switchgear panels
Motor starting studies for large drive applications
Root-cause analysis for panel tripping and nuisance fault events
Nuisance tripping investigation, diagnosis, and resolution
Protection coordination characteristic curve generation
EMTP (Electromagnetic Transients Program)
Insulation coordination
Grid integration studies for solar and wind
EMTP switching studies
Complete electrical network study with full calculation report and Kahramaa documentation
Kahramaa, Qatar Energy, Client approvals
St. Regis Hotel, Katara
Nuisance tripping investigation -> protection coordination study -> revised settings -> Kahramaa approval -> tripping eliminated
Qatar Foundation
11kV chiller feeder tripping -> power system study -> settings revision -> tripping resolved
Oasis Mall
Short circuit and protection coordination for 11kV substation with YY bus configuration
Qatar University
Short circuit and protection coordination for 11kV substation with YY bus configuration
Falcon 5 Project
Load flow, short circuit, and coordination across 25 LV panels (1,000 / 1,600 kVA)
Lusail District Cool Marafeq
Load flow, short circuit, and coordination for 11 MV panels with chiller feeders
Lusail Marina DCP
Full study: network analysis, short circuit, coordination, harmonics, and neutral grounding
ISF (Lekhwiya)
33kV panel: load flow, short circuit, voltage drop, and protection coordination
SW1 Pumping Station, Lusail
11kV relay coordination, motor starting, and root-cause tripping analysis
Lusail North DCP
Full study: coordination, relay settings, motor starting, short circuit, and harmonic analysis
QTEC
Arc flash studies for LV switchgear panels
Ooredoo
Load flow and short circuit studies for LV distribution panels
Qatar Energy
Load Flow Study; Short Circuit Study for 33kV network; Protection ETAP Studies of LV Panel - including load flow calculations with MCCBs ratings, voltage drop calculations, and protection coordination characteristic curves
Al Dayen Coast Guard
11kV protection coordination study for chiller feeder networks
HMC Car Parking
Load flow, short circuit, and coordination for 11kV substation
Al Wakra/Wukair-STP
Protection Coordination Study; Operational Sequence designing


Study: TCC Curve Optimization
A comparison of 'Incorrect' vs 'Proper' coordination, demonstrating how our engineers eliminate nuisance tripping and improve grid reliability.



Technical parameters and scope parameters that define our service delivery.